Lighting tower and lighting support system inspection

Non-destructive testing, structural certification and condition assessment of public and industrial lighting columns

Why inspections are necessary

Prevention through NDT makes it possible to avoid sudden failures and guarantee service continuity.

Lighting columns are subject to:

Inspection and certification services

1. Non-destructive testing on lighting columns

The inspections include specific NDT techniques to detect internal defects, corrosion and loss of section:

Ultrasonic examination (UT / thickness measurement)

  • Measurement of residual thickness
  • Estimate of corrosion progression
  • Detection of internal anomalies

Magnetic particle testing (MT) / Penetrant testing (PT)

  • Detection of surface and sub-surface cracks
  • Analysis of welds and joints
  • Inspection of bolted connections

Thermography (TT)

  • Identification of areas with thermal anomalies
  • Location of hidden defects

LPR technique

  • Inspection at the base

Visual testing (VT) and video inspection

  • General inspection of the column
  • Analysis of bases, flanges, attachment points, access hatches and steelwork
  • Detection of deformation, oxidation and deterioration

2. Structural inspection of lighting towers

STIGC carries out:

  • analysis of the verticality and stability of the structure
  • inspection of the bolted connections
  • inspection of the pole base and foundation plates
  • verification of load and oscillation conditions
  • assessment of the integrity of joints, arms and crossbeams

3. Classification of the state of conservation

Using NDT data and structural parameters:

  • calculation of section loss and reduction in strength
  • definition of the risk class
  • recommendations for maintenance, repair or replacement

4. Certification and technical report

Every job includes:

  • a technical report with the test results
  • photographic and instrumental records
  • thickness values and residual-life estimates
  • certification of the integrity status of the lighting tower or pole inspected
  • operating recommendations and maintenance plans

Fields of application

Why choose STIGC

Personnel certified to UNI EN ISO 9712

NDT specialists for lighting towers and public lighting.

Advanced inspection technologies

Ultrasonics, magnetic particle testing, penetrant testing, thermography, video inspection.

A complete structural approach

From the foundation base to the pole body and the lifting arms.

Certified report and full traceability

Documentation compliant for audits, inspections, maintenance and operator liability.

On-site work, with no interruption to service

Fast, non-invasive inspections that can also be carried out on live installations.

Request a tailored quote

Reply within 24 hours, regulatory advice included.

Procedures, certifications and operating methods

Frequently asked questions about our services

Lighting towers, public lighting poles, industrial columns and support systems for sports or infrastructure installations.

Non-destructive testing such as ultrasonics (UT), magnetic particle testing (MT), penetrant testing (PT), thermography (TT) and visual examination (VT).

Residual thickness, corrosion, stability of the structure, bolted connections, foundation plates and the condition of the joints.

Yes: a technical report, photographic records, thickness measurements and an assessment of the structure’s integrity.