Open-top tank inspection
Leak-tightness and structural integrity testing for underground and above-ground tanks – certification in accordance with the applicable standards
Professional leak-tightness testing of open-top tanks
Open-top tank inspections are a regulatory requirement that applies to most industrial facilities subject to Italian A.U.A./A.I.A. environmental permits. Inspecting open-top tanks, in particular those that are underground or used to store water, wastewater or process substances, is essential in order to guarantee:
- no leaks
- structural integrity
- environmental protection
- compliance with current regulations
- safety of the industrial site
STIGC performs leak-tightness and functional testing using certified methods, issuing official documentation for inspection, environmental and maintenance purposes. If you have doubts about the integrity or regulatory compliance of your tanks, or of the systems that contain and collect technological first-flush rainwater – which are also subject to statutory inspection – you can contact us for a free consultation.
What we check
The inspections apply to tanks that are:
- underground, open-top
- semi-underground
- made of concrete, steel or composite materials
- above ground
- used for industrial water, rainwater, wastewater, sludge collection, process vessels, containment or balancing tanks
Types of inspection carried out
1. Hydraulic leak-tightness testing
We check that the tank shows no:
- direct leaks or leakage by run-off
- seepage to the outside
- water rising from the ground
- anomalies related to hydrostatic pressure
The tests are carried out using recognised technical methods, with level monitoring and analysis of the variations.
2. Structural integrity inspection
Through visual and instrumental analysis we check for:
- cracks, fissures or deterioration of the concrete
- detachment of protective linings
- corrosion of metal parts
- local settlement or deformation
- infiltration from the sides or the bottom
3. Containment test and functional assessment
The tank is monitored over an observation period, assessing:
- its capacity to hold the design volume
- any losses invisible to the naked eye
- interference with the water table or the surrounding ground
4. Photographic survey and technical documentation
Every inspection includes:
- a detailed report with the test results
- measured values
- photographic records
- recommendations on any work required
- certification of the leak-tightness and integrity of the tank
Methods used
- Level monitoring
- Technical visual inspection (VT)
- Leak detection
- Lining inspection
- Assessment of in-service behaviour
- Analysis of infiltration and critical points
(Consistent with the tests applied to underground tanks and pipework described in UNI EN 1610:2015 for similar systems)
When to carry out the inspection
1
New installation or recommissioning
2
Change of use or plant upgrade
3
Scheduled maintenance
4
Suspected leaks or infiltration
5
Environmental or permit-related checks
6
Requests from the supervisory authority or the site operator
Why choose STIGC
Specialisation in underground structures and containers
Expertise built up in industrial inspection, testing and maintenance services.
Reliable, documented technical methods
Every test is carried out with certified instruments and compliant procedures.
Certification of leak-tightness and integrity
Official documentation that can be used for internal audits, supervisory bodies, operators and environmental authorities.
Assessment of the state of conservation
Clear guidance on any work required.
Complete technical support
From scheduling the tests to managing inspection deadlines.
Request a tailored quote
Reply within 24 hours, regulatory advice included.
Procedures, certifications and operating methods
Frequently asked questions about our services
Underground, semi-underground or above-ground tanks in concrete, steel or composite materials, for water, wastewater or process substances.
Level monitoring and checks for any leaks, infiltration or anomalies related to hydrostatic pressure.
Yes, through technical visual inspection and checks on cracks, corrosion, settlement, linings and infiltration.
Yes: a technical report, photographic records, measured values and certification of the tank’s leak-tightness and integrity.